Can I reverse-solve stairs from tread count?
Not in v1. Stair geometry stays single-direction so riser rounding and code checks remain explicit and predictable.
Solve stair geometry from total rise with IRC or IBC reference checks.
Plan for — risers at the code-max — in each, with 11.25 in tread depth.
Run multiple stair calculations on one page (for example, a front porch stair and a deck stair). Only the active run's result feeds the material list.
Lettered callouts match the field names below: A Total Rise, B Tread Depth, C Tread Thickness, D Steps on Stringer, E Height of First Step, F Typical Step Height, G Total Run, H Stringer Placement Below Landing.
Choose a solve mode, then fill in only the fields it needs.
Code mode, tread thickness, stringer mount type, and headroom — sensible defaults are already filled in.
Plan for — risers at the code-max — in each, with 11.25 in tread depth.
Plan for
Included: riser/tread layout, stringer length, riser height, tread depth and headroom checked against the 2021 IRC (residential) or IBC (commercial), 2 x riser + tread comfort checks — jobsite rules of thumb, not code.
Not included: labor, permits, engineering review or stamped plans, fasteners and connectors unless explicitly itemized above.
IRC R311.7.5.1: riser height not more than 7.75 in. The IRC sets no minimum.
The 11.25 in cap applies to the comfort default only -- it is the width of one board, not a code limit. IRC R311.7.5.2 sets a minimum tread depth (10 in here) and no maximum. The 17.5 in in the comfort default is the trade's rise-plus-run rule of thumb: estimated jobsite practice, NOT a code figure and not read from any published table.
Standard mount lets the landing framing form the top riser; flush mount cuts every riser into the stringer itself.
Enter total rise, pick a code mode, and CrewMeasure calculates risers, treads, stringer length, and comfort warnings.
Not in v1. Stair geometry stays single-direction so riser rounding and code checks remain explicit and predictable.
It compares twice the riser height plus tread depth against a common 24 to 25 inch comfort target and warns when it falls outside that range.
Headroom depends on the surrounding structure, so the calculator flags low clearance when your entered value drops below 80 inches.
This is a general reference only. Verify local code, field conditions, headroom, and final stair layout before construction.